Henan Jinshui Cable Group Co., Ltd.
Products
Contact Us
  • Contact Person : Mr. JS JINSHUI
  • Company Name : Henan Jinshui Cable Group Co., Ltd.
  • Tel : 086-371-67849797
  • Address : Henan,zhengzhou,No. 82, West Part of Kexue Avenue, High and New Technology Development Zone, Zhengzhou City, Henan Province. China
  • Country/Region : China
  • Zip : 450001

Al stranded conductor and ACSR

Al stranded conductor and ACSR
Product Detailed
Related Categories:Power Cables
ACSR wire is designed for aerial electricity transmission and distribution lines ACSR(Aluminum Conductor Steel Reinforced) is widely used in the overhead power distribution system of our country. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, ASTM B232, CSA C49, DIN48204, JIS C3110, customer special specification also can be satisfied. All Aluminum Conductor(AAC)& Aluminum Conductor Steel Reinforced(ACSR))for ASTM (AAC, ACCR, AAAC, ACSR) Generally Confirming to IS 398 (Part-I, II, IV), IEC-228 (AAAC) Conductor as per ASTM-B-399-1992 (AAAC) Conductor as per BS-3242-1970 (AAAC) Conductor IS: 398-IV-1994 (ACSR) as per ASTM-B-233-1992 (AAC) as per BS-215-1-1970 (AAC) as per IS-398-1: 1976 (AAC) as per ASTM-B-231-1990 (ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992 (ACSR) BS-215-II-1970 (AACSR) as per IEC-1089-1191 AAC(All aluminum conductor) are suited for overhead power line. We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied. ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power Applications Used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity. Construction Aluminum alloy 1350-H-19 wires, concentrically stranded about a steel core. Core wire for ACSR is available with class A, B, or C galvanizing; ""aluminized"" aluminum coated (AZ); Or aluminum-clad (AW). Additional corrosion protection is available through the application of grease to the corer or infusion of the complete cable with grease. Specifications ACSR bare conductor meets or exceeds the following ASTM specifications: B-230 Aluminum Wire, 1350-H19 for Electrical Purposes B-231 Aluminum Conductors, Concentric-Lay-Stranded B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR) B-341 Aluminum-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR/AZ) B-500 Zinc Coated and Aluminum Coated Stranded Steel Core for Aluminum Conductors, Steel Reinforced (ACSR) Notes Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions. Current ratings are based on 75oC conductor temperature, 25oC ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.The data sheets below show part spec of IEC61089Code Number Stranding&Wire Diameter Approx Sectional Area ApproxWeight Breaking Load DC Resistance Overall Al Steel Diameter Al Steel Total mm mm mm mm 2 mm 2 mm 2 Kg/km KN Ohm/km 16 6/1.84 1/1.84 5.53 16 2.67 18.7 64.6 6.08 1.7934 25 6/2.30 1/2.30 6.91 25 4.17 29.2 100.9 9.13 1.1478 100 6/4.61 1/4.61 13.8 100 16.7 117 403.8 34.33 0.2869 125 18/2.97 1/2.97 14.9 125 6.94 132 397.9 29.17 0.2304 160 18/3.36 1/3.36 16.8 160 8.89 169 509.3 36.18 0.18 250 22/3.80 7/2.11 21.6 250 24.6 275 880.6 68.72 0.1154 400 54/3.07 7/3.07 27.6 400 51.9 452 1510.3 123.04 0.0723 450 54/3.26 7/3.26 29.3 450 58.3 508 1699.1 138.42 0.0643 500 54/3.43 7/3.43 30.9 500 64.8 565 1887.9 153.8 0.0578 560 54/3.63 19/2.18 32.7 560 70.9 631 2103.4 172.59 0.0516 630 54/3.85 19/2.31 34.7 630 79.8 710 2366.3 191.77 0.0459 710 54/4.09 19/2.45 36.8 710 89.9 800 2666.8 216.12 0.0407 800 72/3.76 7/2.51 37.6 800 34.6 835 2480.2 167.41 0.0361 900 72/3.99 7/2.66 39.9 900 39.9 939 2790.2 188.33 0.0321

Al stranded conductor and ACSR



Copyright Notice @ 2008-2022 ECBAY Limited and/or its subsidiaries and licensors. All rights reserved.